Install, update and restore
Update
On the player. Copy orpheus-<version>.ofw to the top folder of the
card (or /.orpheus/update/), then Settings › System › Update firmware:
choose the file, read its changes, Install. The player checks the whole
file, writes it next to the running firmware, reads it back, switches and
restarts. Keep 30 % battery or the cable in; music, settings and the card
stay.
From a computer. Open the site's Install page in Chrome, Edge, Opera or Brave, Choose the player, Update Orpheus. No driver is needed. Or, from the project's tools:
cargo xtask build # also writes orpheus-<version>.ofw
cargo xtask dev update target/orpheus/orpheus-*.ofw
A power cut during an update is harmless: the player starts either the previous version or the new, complete one.
If the new version does not start
After three failed starts the player starts the previous version by
itself (Settings › System › About then shows Failed to start). If that
fails too, it goes to recovery mode (its chip's USB recovery, which
nothing can overwrite). On the Install page, Choose the player again,
then Recovery › Start the other firmware. With the tools: cargo xtask dev switch-slot, then cargo xtask dev reset.
First install
On a player with the original firmware the Install page does it in recovery mode:
- Back up the whole flash: read twice and compared, kept in the browser and downloaded as a file. Keep that file.
- Confirm that the next step rewrites the boot record, then First install of Orpheus. If it is interrupted, the page offers to continue.
The original firmware has no button for recovery mode: the first time,
cargo xtask dev adfu (Linux) switches it. On Windows, recovery mode
needs the WinUSB driver once (for example with Zadig, device
10D6:10D6).
The command-line way, on the reference player, was:
cargo xtask dev nordump 0 0x800000 local/nor-before-full.bin,
cargo xtask dev backup-verify, cargo xtask dev install-stage2,
cargo xtask dev install-full --i-have-a-backup. The tools still need the
companion repository
yoton-rockbox for two small
helper programs (point ORPHEUS_DIR at it) and the udev rule:
sudo cp tools/udev/99-orpheus.rules /etc/udev/rules.d/
sudo udevadm control --reload && sudo udevadm trigger
Restore the original firmware
On the Install page in recovery mode: choose the backup (the one the page kept, or the downloaded file), confirm, Restore the original firmware. Every part of the flash that differs from the backup is written back, the boot record last but one; the data the original firmware keeps at the end of the chip is never touched. With the tools:
cargo xtask dev restore vendor --verify # compare only
cargo xtask dev restore vendor --i-have-a-backup # write it back
How the player is laid out
Orpheus uses the flash from 0x001000 to 0x7DFFFF: two firmware slots
(an update goes into the one not running), its settings and a 1 KiB boot
stage. The first 4 KiB (the boot record) are written only by the
confirmed steps above, never by an update; the last 128 KiB (data the
original firmware left) are never written. See troubleshooting.